Phone
+8618888300248With a wide air flow range and low pressure drop design, it is suitable for industrial installations of various sizes.
Air Flow Range
Low Pressure Drop
Ambient Temperature
Optimized heat exchange structure for rapid condensation of water vapor and efficient gas-water separation.
The airflow cross-sectional area within the heat exchanger and compressed air connector is large, with a pressure difference ≤0.3 bar.
Ensure compressed air is dry to reduce condensation buildup in the air delivery system.
Compatible with the entire range of UMW Air air compressors to meet the air needs of different industrial sectors.
Covering everything from small workshops to large air compressor stations.
Intelligently and automatically drains condensate, reducing manual maintenance.
Can be flexibly combined with air compressors, air tanks, precision filters.
Cool the compressed air before it enters the production line to remove condensate.
With an airflow range from 1.2 to 90 m³/min, UMW Air refrigerated air dryers support different compressor capacities across Micro, Prime, Core and Mega Series.
1.2-90
m³/min
Micro / Prime / Core / Mega
Electronic condensate drainers are installed as standard equipment, providing reliable condensate separation without pressure loss. They are also insulated to prevent condensate formation.
No manual drainage required
Prevents condensate backflow into the pipes
Ensuring continuous and stable system operation
Optimized heat exchange structure and smooth airflow channels reduce air resistance, maintain stable delivery pressure and lower compressor energy load.

4-7.5kW
1.2 m³/min

11-22kW
3.8-5.2 m³/min

30-110kW
8.2-28 m³/min

132-355kW
80-90 m³/min
Selection based on compressor power and airflow helps avoid under-sizing, over-sizing and unnecessary energy waste.
| Parameter | Details |
|---|---|
| Matching Compressor Power | 4–355 kW |
| Air Treatment Capacity | 1.2–90 m³/min |
| Pressure Dew Point | 2–10°C |
| Pressure Drop | ≤0.3 bar |
| Working Pressure Options | 6–25 bar, model dependent |
| Ambient Temperature | ≤45°C |
| Refrigerant | R134A / R410A |
| Cooling Method | Air-cooled |
| Connection Size | G1/2 to DN200 |
| Condensate Drainage Method | Automatic drainage |
The air dryer should be selected according to the compressor air delivery, working pressure, inlet air temperature, ambient temperature. In most cases, the dryer capacity should be equal to or slightly higher than the compressor output.
A 2–10°C pressure dew point means the dryer can cool compressed air and remove moisture to help reduce condensation in the air system. It is suitable for most general industrial compressed air applications.
Lower pressure drop helps reduce unnecessary pressure loss in the compressed air system. This can help reduce compressor load, maintain stable air delivery, and improve overall system efficiency.
Yes. UMW Air refrigerated air dryers include multiple pressure options, with selected models supporting higher working pressure requirements up to 20–25 bar depending on configuration.
Yes. A refrigerated air dryer mainly removes moisture from compressed air. For better air quality, it is recommended to use suitable filters to remove oil mist, particles, and other contaminants.
Please provide compressor power, air delivery, working pressure, inlet air temperature, ambient temperature, and application. Based on this information, UMW Air can recommend a suitable dryer and filter configuration.
Tell us your air flow, working pressure, voltage and application. Our engineers will help recommend a suitable refrigerated air dryer and compressed air treatment solution for your factory.
68 Gongye South Road, Jinan, Shandong, China, 250000
Tell us your required pressure, air flow, voltage and application.
Please complete the form below to request your quote. We will be in contact as soon as possible.